Knowledge Base › Fluid Systems Error Case › Gas-Liquid Two-Phase Flow at Pump Inlet

Gas-Liquid Two-Phase Flow at Pump Inlet

E44-1047 · Two-Phase Flow and Gas Binding · Pump Inlet · ★★★

Problem Description

Two-phase flow, erosion, noise

Root Cause

[Mechanism] Gas accumulated at high points in the pump inlet line or the medium vaporized; the pump drew in a gas-liquid two-phase flow, the impeller cavitated, and output dropped.
[Calculation] Inlet gas fraction 4%; pump Q fell from 100m³/h to 60; NPSHa=3.0m while NPSHr=3.2m (short by 0.2m); cavitation resulted.
[Design Omission] No gas separation, no high-point venting, and no NPSH check.

Corrective Solution

1) Provide venting at inlet high points (DN20 continuous vent); gas entry caused two-phase flow, and venting restores pure liquid, recovering flow;
2) Check NPSHa≥NPSHr+0.5m (was short by 0.2); insufficient margin causes cavitation, and raising it protects against cavitation;
3) Raise the inlet pressure (lower the installation height by 1m); low inlet pressure causes cavitation, and raising pressure protects against two-phase flow;
4) Make the inlet line slope uniformly with no reverse slope (no gas pockets); sags trap gas, and a uniform slope vents it, leaving no gas;
5) Run a cavitation test (monitor NPSH margin ≥0.5m); two-phase flow was never checked, so measured data confirms pure liquid, sizing the suction by data;
6) Install an inlet vacuum gauge plus gas-liquid monitoring (gas fraction ≤1%); two-phase flow first shows up as a vacuum change, so early warning gives phase monitoring;
7) In operation, control the level (suction sump ≥0.5m margin); a low level causes air drawing, and level control stabilizes it, preventing two-phase flow in service;
8) Write gas separation and NPSH check into the calculation report; the root cause of inlet two-phase flow is no venting and insufficient NPSH, so calculations gate it.

Checklist

Reference

GB/T 5657-1995 Technical specifications for centrifugal pumps

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL