E44-422 · Two-Phase Flow and Gas Binding · Orifice Plate with High Pressure Drop · ★★
The orifice pressure drop drives the downstream flow to choking (sonic speed), the flow is limited, and the downstream section is starved of feed.
[Mechanism] The pressure drop drives the downstream flow to sonic speed, choking and limiting it.
[Calculation] The flow limit starves the downstream section of feed.
[Design Omission] Choked flow was not checked and the orifice was wrongly sized — the cause of the choking.
1) Recheck the orifice pressure drop to avoid choking (limit Δp/p1 <0.9); reaching sonic speed limits the flow and starves the feed, so control the drop;
2) Enlarge the orifice bore to raise the choked limit; a small bore chokes easily, so enlarge it;
3) Check the flow with the choked-flow equation; rough estimates understate it, so calculate accurately;
4) Switch to multi-stage throttling to share the pressure drop; a single stage chokes easily, so stage it;
5) Fit a downstream buffer tank to stabilize supply; the flow limit makes supply unstable, so buffer it;
6) Periodically measure the actual flow; restriction builds gradually, so measure it;
7) Hold the upstream pressure steady; pressure changes shift the choking point, so control the pressure;
8) Write the choking check into the design; the original lack of checking was the root cause of the restriction, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps