Knowledge Base › Fluid Systems Error Case › Clogged Filter with Large Pressure Drop

Clogged Filter with Large Pressure Drop

E44-678 · Hydraulic System Contamination and Stick-Slip · Filter · ★★

Problem Description

Clogging, pressure drop >0.3 MPa

Root Cause

[Mechanism] Clogging causes a large pressure drop.
[Calculation] Clogging makes the pressure drop >0.3 MPa.
[Design Omission] No element change, no bypass, and no inspection were provided, causing clogging.

Corrective Solution

1) Change filter elements on schedule (every 2000 h or at 0.35 MPa differential pressure); because the clogged element raised the pressure drop from 0.05 to 0.4 MPa and caused pump cavitation noise, a new element lowers the drop and restores flow;
2) Add a differential-pressure alarm (indicator switch, alarm Δp >0.3 MPa); because clogging is gradual and early warning prevents sudden flow loss, this gives warning;
3) Add a bypass check valve (opens at 0.4 MPa, against oil-flow interruption); because a fully clogged element cuts supply and the bypass keeps it going, this maintains supply;
4) Use higher dirt-holding-capacity elements (dirt capacity ≥200 g, β10 ≥200); because low capacity clogs easily and higher capacity lasts longer, this extends element life;
5) Monitor differential pressure (online, trend recorded); because clogging is quantified by the trend and monitoring times the element change, this follows the data;
6) Control contamination level (NAS 8); because high contamination clogs the filter and control reduces it, this lowers clogging;
7) Clean the filter head (at every element change, remove residue); because residue buildup clogs and cleaning removes it, this eliminates the source;
8) Write element change and alarm into the maintenance card (differential-pressure indicator); because the original lack of element change is the root cause of clogging and fixing it closes the loop, maintenance enforces control.

Checklist

Reference

GB/T 3766-2015 General technical conditions for hydraulic systems