E44-934 · Siphon and Backflow · Vessel · ★★
Reverse flow, reversed level, disorder
[Mechanism] Two vessels are cross-connected, and the medium in the higher one flows backward through the connecting pipe into the lower one, disrupting the level order.
[Calculation] At ΔH=1.6 m the reverse flow is v≈0.85 m/s and 0.5 m³/h, throwing the level gauge readings into disorder.
[Design Omission] No check valve, no elevation-difference check, and no one-way control.
1) Install a check valve in the connecting pipe (one-way isolation), because the elevation difference drives reverse flow and the check valve cuts off the source, thereby preventing the higher vessel from surging into the lower one;
2) Check the elevation difference so it decreases along the flow direction (the following vessel lower than the preceding one), because a positive difference eliminates the reverse driving force and the layout prevents reversal, thereby stabilizing the order;
3) Provide fast shutoff in the critical pipe (pneumatic ≤2 s) interlocked on level, because a changed condition causes reversal and fast shutoff limits the volume, thereby controlling the volume and reducing disorder;
4) Provide an independent level gauge and alarm on each vessel (alarm on abnormality), because reverse flow first shows as an abnormal level before the full disruption, thereby monitoring the level for early warning;
5) Perform a reverse-flow test (simulate a pump stop and verify no surging), because the design omitted the difference check and the test confirms the isolation effect, thereby verifying the isolation;
6) Control the level difference between the two vessels ≥0.2 m with an alarm, because a stable difference prevents reverse flow and controlling it prevents disorder, thereby preventing disturbance in operation;
7) Add a flow meter to the connecting pipe (alarm on reverse flow), because reverse flow shows immediately and is cut off early, thereby monitoring the flow to prevent reversal;
8) Write the check valve and elevation-difference checking into the vessel regulations, because the root cause of reverse flow is a reversed difference without isolation, so the regulations must govern to prevent disorder.
GB/T 20801.3-2020 Design code for industrial metallic piping