E44-665 · Level Control Failure · Drain pump · ★★★
Started low, ran dry, cavitated
[Mechanism] Starting at a low level runs the pump dry.
[Calculation] A low level runs it dry.
[Design Omission] No interlock, no start delay and no checks were provided — so the pump started low.
1) Provide a low-low interlock with start delay (the pump stops at a level ≤15% with a 30s delay): because the original start at low level ran the pump dry and cavitated, the delay waits for the level to recover and protects the pump, so it does not run dry;
2) Verify the low start point to prevent error (low start ≤10% of range): because a point that is off starts too low and calibrating it makes it accurate, the start is correct;
3) Add dry-run protection (a vibration switch trips the pump at ≤4.5mm/s): because running dry damages it and the protection stops it, the pump is protected;
4) Select an adequate NPSH margin (pump NPSHr margin ≥0.5m): because too little margin runs it dry and enough keeps it stable, it tolerates a low level;
5) Monitor the level with low alarms (a low alarm plus a low-low display): because a low level runs it dry and monitoring gives warning, it stops early;
6) Check for dry-run noise (listen for abnormal sound or check the vibration velocity): because gradual dry running damages it and checking gives early warning, it is stopped in advance;
7) Limit the start frequency to prevent a low level (start / stop interval ≥5min): because frequent starts lower the level and limiting them keeps it steady, the level is controlled;
8) Write the interlock and delay into the control card: the original absence of an interlock was the root cause of the low level, so the card locks it in and control governs it.
GB/T 13007-2011 Centrifugal pumps