E44-718 · Hydraulic System Contamination and Crawling · Online Monitoring · ★★
No monitoring, contamination undetected
[Mechanism] Without monitoring, contamination goes undetected.
[Calculation] Missing monitoring lets contamination accumulate.
[Design Omission] No monitoring, no alarm, and no inspection - a design defect leading to undetected contamination.
1) Install an online particle monitor (laser, real-time NAS); without monitoring the contamination had built up until the valve jammed unnoticed, so online monitoring reveals it;
2) Set an exceedance alarm (alarm at NAS>9); exceeding the limit jams the valve, so the alarm gives early warning;
3) Interlock with filtration (start the bypass on exceedance); exceeding the limit triggers filtration, so the system cleans itself automatically;
4) Check monitor accuracy (calibrate, adjust any deviation); a biased monitor gives wrong readings, so calibration keeps it reliable;
5) Keep a trend file (store data, track trends); running blind lets contamination accumulate, so the file makes trends visible and traceable;
6) Schedule quarterly monitor calibration (reference samples); gradual drift is invisible, so calibration keeps it accurate and reliable;
7) Control contamination to prevent jamming (NAS 8); high contamination jams the valve, so control reduces jamming;
8) Write online alarm points into the control card (monitoring point layout); since lack of monitoring was the root cause, fixing it in the control card gives control-system oversight.
GB/T 3766-2015 General technical conditions for hydraulic systems