E44-468 · Filter Clogging and Contamination · Paint Filter 100 Mesh · ★★
Skinning paint particles plug the screen, the spray gun loses feed, the coating oranges, and the re-spray rate rises 20%
[Mechanism] Flocculated paint particles jam the screen openings.
[Calculation] Particles d=150μm exceed the 106μm screen openings, 40% of openings are jammed, feed Q drops, and the spray pattern breaks.
[Design Omission] No anti-settling agent and no regular screen cleaning, so the gun clogged.
1) Add an anti-settling agent to the paint and keep it stirred to prevent flocculation; since flocculation with d=150 exceeding 106 jammed 40% of openings, preventing flocculation keeps feeding smooth;
2) Make the screen removable for quick cleaning and clean it every shift; since buildup causes plugging, frequent cleaning prevents it;
3) Pre-screen through a 40-mesh screen before spraying to remove agglomerates; since agglomerates jam the screen, pre-screening removes them;
4) Add agitation ahead of the pump to prevent settling; since settling causes plugging, agitation prevents it;
5) Add a fine filter before the gun as double protection; since a single filter can bypass, double filtering backs it up;
6) Control paint viscosity to avoid thickening; since thick paint jams the screen, viscosity control prevents it;
7) Stabilize feed pressure to prevent pulsation-induced pattern breaks; since pulsation breaks the spray pattern, pressure stabilization prevents it;
8) Write anti-settling and screen cleaning into the coating procedure; since the lack of prevention was the root cause of clogging, the coating procedure provides the check.
GB/T 26114-2010 Filters for liquid filtration