Insufficient Rebound of a Serrated Gasket Causes Temperature Leakage

E44-566 · Seal Leakage · High-Temperature Flange · ★★

Problem Symptom

Leakage, thermal cycling opens a 0.1mm gap, rebound insufficient

Root Cause

[Mechanism] Thermal cycling reduces the rebound of the gasket.
[Calculation] A 150C temperature change opens a 0.1mm gap and the rebound drops below 5%, so it leaks.
[Design Omission] A high-rebound gasket was not selected, no preload was applied, and no compensation was provided - the rebound was insufficient.

Correct Solution

1) Change to a high-rebound gasket (a corrugated bellows gasket, rebound >15%); the original rebound below 5% and the 0.1mm gap opened on cooldown leaked, so a higher rebound compensates the gap and stops the leak;
2) Preload to 80MPa (pre-deform the gasket); without preload a gap opens on cooldown, so preloading fills the gap;
3) Add Belleville spring compensation for cooldown (a disc spring stack takes up the slack); cooldown loosens the bolts and opens a gap, and the springs compensate;
4) Control the temperature change to <=80C (heat and cool slowly); a large change opens the gap, so controlling the rate prevents it;
5) Select a soft steel serrated gasket (08F soft steel, easy to spring back); a hard material has low rebound, so soft steel raises the rebound;
6) Hot-tighten to restore the pressure (re-tighten once the operating temperature is reached); cold shrinkage loosens the joint and hot-tightening restores it;
7) Set a routine rebound inspection (measure the recovery rate on dismantling); the rebound falls gradually and then leaks, so the rebound is inspected;
8) Write the high-rebound gasket and the preload into the specification; the original failure to select a resilient material was the root cause of the insufficient rebound, so the specification closes the loop.