E44-265 · Valve Selection and Internal Leakage · Plunger valve U41S-16 DN50 · ★★
Packing-box external leakage 1.5L/min; only 2 seal rings (design ≥4); packing re-tightened 3 times a month
[Mechanism] Only 2 seal rings spread seating pressure thinly, overloading each ring until it leaks.
[Calculation] Scoring on the plunger turns the ring's line contact into a poor face contact.
[Design Omission] Ring count was not chosen by pressure and plunger surface finish was uncontrolled - the plunger valve leaked.
1) Raise seal rings to 4-5, since the 2 rings spread pressure thinly and one overloaded to leak 1.5L/min, sharing pressure to meet the target;
2) Polish the plunger to Ra0.4 and harden it, since scoring turned line contact into a poor face contact, sealing on a smooth surface;
3) Add constant disc-spring load to compensate wear, since wear drops compression, holding constant pressure;
4) Re-tighten hot periodically and mark positions, since it gradually loosens, re-tightening to the marks;
5) Switch to a metal bellows seal at high temperature, since packing eventually creeps, cutting off external leakage;
6) Add a leak-collection sump, since external leakage is a loss, keeping it controlled;
7) Select ring count by pressure, since high pressure needs more rings, ensuring enough rings;
8) Write ring count and finish into the design, since the insufficient original design caused the leak, closing the loop at design.
JB/T 11151-2011 Plunger valves