E44-266 · Valve Selection and Internal Leakage · Outside-screw gate valve Z41H-16 DN100 · ★★
Stem-nut trapezoidal-thread wear 0.6mm (design ≤0.2); operating torque is 2× rated and it jams shut
[Mechanism] Frequent operation wears the bronze nut threads, widening clearance and breaking power transmission.
[Calculation] Overload pushes thread-root shear stress past the allowable, stripping the threads.
[Design Omission] No wear-resistant nut and no cycle limit - the gate valve jammed.
1) Switch the nut to bronze or a hardfaced wear layer, since the worn 0.6mm threads (over 0.2) broke transmission, wearing better and lasting longer;
2) Limit cycle frequency and add lubrication, since frequent operation is the wear source, reducing wear;
3) Add torque-limit protection, since overload pushed root shear past allowable and stripped it, limiting force to protect the threads;
4) Add a hard coating to the stem to cut paired wear, since soft-on-hard wears fast, a hard face lowers wear;
5) Measure thread clearance periodically and replace early, since wear is gradual, diagnosing early;
6) Switch from inside-screw to outside-screw to see travel, since an invisible stem hides the opening and invites over-torque, making it visible;
7) Add gearing on large sizes to cut hand force, since high hand force invites over-torque and stripping, saving effort;
8) Put nut material and maintenance into the procedure, since the lack of control was the strip root cause, closing the loop in O&M.
GB/T 12232-2005 General purpose valves - Flanged iron gate valves