E44-607 · Seal Leakage · Mechanical Seal Cooling · ★★
Cavitation in the seal cavity and leakage, high temperature
[Mechanism] Insufficient cooling causes cavitation.
[Calculation] The high temperature vaporises the liquid, damages the faces and it leaks.
[Design Omission] No cooling was provided, the temperature was not controlled and the seal was not selected - the cooling was insufficient.
1) Provide mechanical seal cooling water (0.3MPa, flow rate calculated from the heat load); the original insufficient cooling let the cavity overheat, the medium vaporised and cavitated, damaging the faces and leaking, so cooling stops the cavitation;
2) Control the cavity temperature at <=70C (temperature transmitter with interlock); a high temperature causes cavitation, and cooling prevents that;
3) Select a cavitation-resistant seal face pair (silicon carbide hard face); cavitation damages it, and a cavitation-resistant pair prevents that;
4) Raise the inlet pressure to prevent cavitation (raise NPSHa to at least twice the cavitation margin); a low pressure causes cavitation, and raising the pressure prevents it;
5) Monitor the temperature with an alarm (above 70C); a high temperature causes cavitation, and monitoring gives warning;
6) Purge the cooling circuit to remove vapour (air vent valve); accumulated vapour causes cavitation, and purging prevents that;
7) Set a routine face damage inspection (PT at every overhaul); damage develops gradually and then leaks, so the face is inspected;
8) Write the cooling and the temperature control into the specification; the original absence of cooling was the root cause of the cavitation, so the specification closes the loop.
GB/T 14211-2019 Technical Conditions of Mechanical Seals