E44-1088 · Other · Vacuum Pump · ★★
Leak, cannot pull, low.
[Mechanism] Seals or piping leaked on the vacuum pump; pumping speed was insufficient and vacuum could not be reached.
[Calculation] System leak rate 5Pa·m³/s; ultimate vacuum fell from 10Pa to 200Pa; could not pull down.
[Design Omission] No sealing, no leak detection, and no check.
1) Check sealing against leaks (replace shaft seal / gaskets); a leak lowers vacuum, and sealing restores pull-down;
2) Find leak points (helium mass spectrometry); a leak lowers vacuum, and detection repairs it, raising vacuum;
3) Replace seals (new parts replacing old); old seals leak, and replacement seals, restoring pull-down;
4) Control temperature steadily (≤60℃ against oil thinning); high temperature leaks, and temperature control protects, suppressing leakage;
5) Run a vacuum test (reach 10Pa); low vacuum was untested, and measured pull-down confirms it;
6) Install vacuum monitoring (alarm on low vacuum); a leak first shows as falling vacuum, and early warning catches it;
7) Set a fixed inspection interval in operation (monthly); long intervals leak, and controlled intervals inspect, preventing leakage;
8) Record sealing and leak detection on the vacuum card; the root cause of vacuum leakage was no sealing and no inspection, so the card must gate it.
GB/T 3164-2007 Vacuum technology