E44-521 · Heat Exchanger Fouling and Insufficient Heat Transfer · Dryer Exchanger Finned · ★★
Inlet dust on fins, K drop, slow drying
[Mechanism] Dust coats the fins and blocks airflow.
[Calculation] Dust lowers α, cuts K by 30%, reduces airflow and slows drying.
[Design Omission] No filtration and no blowing, so dust accumulates.
1) Filter inlet air and blow the fins to restore α; dust on the fins blocks airflow (lower α, K drop 30%, slow drying), so filtering and blowing restore K;
2) Set a sootblowing interval (each shift); dust builds and hardens, so periodic blowing keeps it clear;
3) Add an inlet dust collector to cut dust ingress; high dust loads deposit and overload, so collection reduces the load;
4) Fit an airflow alarm (below baseline); dust reduces airflow and slows drying, so the alarm prevents slowdown;
5) Widen fin spacing (≥5 mm); tight spacing lets dust bridge and block airflow, so wider gaps reduce plugging;
6) Calibrate and stabilize inlet air temperature; temperature swings cause uneven drying, so stabilizing temperature ensures even drying;
7) Inspect fins on schedule (visual / Δp); dust builds and resistance rises, so inspection guides blowing;
8) Write filtration, blowing and dust collection into the dryer procedure; the original design omitted filtration and blowing, the root cause of dust, so the procedure closes the loop.
GB/T 151-2014 Heat exchangers