E44-1094 · Other · Oil-Mist Lubrication · ★★
Uneven, lubrication, poor.
[Mechanism] The oil-mist generator was improperly proportioned and line pressure loss was uneven; oil-mist concentration differed >40% across lubrication points, and bearings starved and wore.
[Calculation] Total supply pressure 0.25MPa; a remote branch lost 0.12MPa, leaving only 0.13MPa; atomized droplet size d50=30μm (should be ≤15); concentration deviation 45%.
[Design Omission] No proportion check, no resistance balancing, no heating against condensation, and no lubrication test.
1) Check the oil-mist proportion (oil:gas = 1:200000 by volume); unevenness causes poor lubrication, and even proportion restores it;
2) Balance branch resistance (equal diameter, equal spacing); bias causes unevenness, and balanced resistance equalizes concentration;
3) Add heat tracing (control 40℃ against condensation); cold causes condensation, and heating keeps the mist even;
4) Control total pressure ≥0.3MPa (make up for loss); low pressure causes unevenness, and adequate pressure stabilizes the mist;
5) Run a lubrication test (concentration deviation at each point ≤10%); untested means unknown, and measured evenness confirms it;
6) Install flow monitoring (alarm on bias); unevenness first shows as a flow difference, and early warning catches it;
7) Adjust point placement (balance near/far); bias causes unevenness, and adjusted points equalize distribution;
8) Record proportion and resistance balance on the lubrication drawing; the root cause of unevenness was biased proportion and uneven line resistance, so the drawing must gate it.
GB/T 3506-2008 Lubricating greases