E44-1093 · Other · Gas-Water Separator · ★★
Poor efficiency, carryover, water.
[Mechanism] The separator was undersized and inlet velocity was too high; gas and water did not separate fully, and downstream equipment carried water and was damaged.
[Calculation] Vessel volume 0.5m³ (should be ≥1.5); inlet gas velocity v=3.5m/s (should be ≤0.8); separation efficiency only 72%; carryover 1.2kg/m³.
[Design Omission] No volume/velocity check, no demister, no inlet distributor, and no separation test.
1) Check volume ≥1.5m³ (replacing 0.5); small volume gives poor separation, and adequate volume separates, restoring separation;
2) Control inlet gas velocity ≤0.8m/s (enlarge diameter or split flow); high velocity carries water, and lower velocity separates, leaving no carryover;
3) Add a wire-mesh demister (efficiency ≥99%); fine droplets carry over, and demisting cleans them, removing water;
4) Check the inlet distributor (even distribution against bias); impingement carries water, and even distribution stabilizes separation;
5) Run a separation test (carryover ≤0.01kg/m³); untested means unknown, and measured separation confirms it;
6) Install level monitoring (alarm on carryover); poor separation first shows as a high level, and early warning catches it;
7) Set a drain interval (continuous automatic); long pooling gives poor separation, and controlled intervals drain, preventing carryover in service;
8) Record volume and demister on the separator drawing; the root cause of poor separation was small volume and high velocity, so the drawing must gate it.
GB/T 150-2011 Pressure vessels