E44-1078 · Other · Ejector · ★★
Weak suction, low pull, low efficiency.
[Mechanism] A worn nozzle or low working-steam pressure lowered suction capacity, leaving vacuum insufficient.
[Calculation] Nozzle erosion enlarged the bore 10%; working steam was 0.8MPa (should be 1.0); vacuum fell from 5kPa to 12kPa, and suction was insufficient.
[Design Omission] No matched nozzle, no steam-pressure raise, and no throat check.
1) Check nozzle matching (replace with a standard nozzle); erosion weakens suction, and replacement restores it;
2) Raise steam pressure to 1.0MPa (was 0.8); low pressure weakens suction, and raising pressure strengthens it;
3) Check the throat diameter (match the enlargement); an off throat weakens suction, and a checked diameter optimizes it;
4) Control back-pressure steadily (≤8kPa); high back-pressure weakens suction, and pressure control protects, suppressing weakness;
5) Run a vacuum test (reach 5kPa); weakness was unchecked, and measured suction confirms it;
6) Install vacuum monitoring (alarm on weakness); weakness first shows as poor vacuum, and early warning catches it;
7) Control cleaning in operation (keep the nozzle clean); scale weakens suction, and cleaning strengthens it, preventing weakness;
8) Record matching pressure and diameter check on the ejector drawing; the root cause of insufficient suction was a worn nozzle and low steam pressure, so the drawing must gate it.
GB/T 10835-2016 Marine steam ejectors