E44-008 · Valve Selection and Internal Leakage · Swing check at a feed-pump outlet · ★★

Problem Description

After shutdown, water reverses and spins the pump back at 120r/min; the next start draws a heavy inrush and contactors burn twice a month

Root Cause

[Mechanism] Wear in the disc pivot pin leaves 0.8mm clearance, delaying re-seating; reverse flow Qt=Av·√(2gH) blows the disc open within 0.5s.
[Calculation] Reverse flow drives the impeller backward, and the starting inrush reaches 6× rated current.
[Design Omission] No fast-closing or slow-closing check chosen and no double non-return protection - the check failed.

Corrective Solution

1) Replace with a fast- or slow-closing check to cut re-seating time to <0.5s, since the slow re-seat was blown open by reverse flow Qt=Av√2gH within 0.5s, cutting off flow immediately after shutdown;
2) Lubricate the disc pivot pin periodically to prevent sticking, since 0.8mm wear clearance delayed re-seating, keeping the pivot free for timely closing;
3) Add a motorized valve at the pump outlet interlocked to shutdown (close first), since an active motorized valve cuts flow faster than a check's passive re-seating, giving double protection;
4) Fit two non-return valves for reliability, since a single failure still leaves a backup, avoiding uncontrolled reverse flow;
5) Add a soft starter to limit the restart inrush after reverse spin, since reverse flow drove the current to 6× rated and burned contactors, current-limiting to protect the motor;
6) Periodically test check-valve action, since pivot-pin wear is gradual, catching delayed re-seating early;
7) Add anti-reverse rotation protection to the motor, since reverse spin damages pump and motor, tripping on anomaly;
8) Write check-valve reliability into the piping protection design, since the missing double protection was the root cause, including it at design stage.

Checklist

Reference

GB/T 12236-2018 Steel swing check valves for petrochemical industry