E44-928 · Siphon and Backflow · Siphon Pipe · ★★
Instability, flow fluctuation, flow stoppage
[Mechanism] Fluctuation of the inlet level together with the moving gas-liquid segment makes the flow pulsate and the siphon unstable.
[Calculation] An inlet level fluctuation of ±0.3 m causes a flow fluctuation of ±12%, and the flow stops without a buffer.
[Design Omission] No buffer, no pressure stabilization, and no velocity control.
1) Provide a surge tank at the inlet (volume ≥ 5 times the pipe volume), because the level fluctuation propagates to the vacuum and the tank absorbs it, keeping the flow steady, thereby suppressing the fluctuation;
2) Add a buffer tank (air capacity ≥ flow × 10 s), because the air cushion shaves the pulsation and reduces the amplitude from ±12% to ±3%, thereby stabilizing the flow;
3) Enlarge the inlet diameter to lower the velocity to 1.2 m/s (originally 1.8 m/s), because low velocity is insensitive to fluctuation and desensitizes the system, thereby stabilizing the flow;
4) Control the outlet control valve in a closed flow loop (PID), because flow fluctuation precedes stoppage and the closed loop stabilizes it, thereby controlling the flow and steadying the suction;
5) Provide a vacuum gauge at the high point with a fluctuation alarm (alarm at >±0.5 m), because an excessive fluctuation precedes stoppage and allows early intervention, thereby monitoring the fluctuation to prevent stoppage;
6) Perform a fluctuation test (apply a step change and verify recovery), because the design omitted stabilization and the test confirms the tank volume, thereby sizing the cushioning from data;
7) Control the flow velocity at 1.2~1.5 m/s to prevent air accumulation (fluctuation promotes air release), because steady flow carries less air and controlling the velocity suppresses vibration, thereby controlling the velocity and steadying the suction;
8) Write the surge tank and buffer into the design regulations, because the root cause of fluctuation is no buffer without velocity control, so the regulations must govern to prevent stoppage.
GB/T 20801.3-2020 Design code for industrial metallic piping