E44-138 · Piping Supports and Thermal Expansion · Tower-top vertical discharge pipe · ★★
The riser has no guide support; medium pulsation gives a lateral amplitude of 4mm and resonates with the main pipe, leaking the flange
[No Guide] The riser's high slenderness ratio gives it a low lateral modal frequency.
[Resonance] The pulsation frequency is near the natural frequency and is amplified.
[Design Omission] No guide support was set and no natural frequency calculated — causing resonance.
1) Add guide supports to the riser to control the lateral displacement: because no guiding gave a low modal frequency and a 4mm lateral amplitude, guiding damps the vibration;
2) Calculate the piping natural frequencies to avoid the pulsation frequency: because a close frequency resonates, the frequencies are calculated to avoid it;
3) Add a damping layer to the support to dissipate energy: because damping cuts the amplitude, damping is applied;
4) Reduce the riser's slenderness ratio with segmental support: because a high slenderness ratio makes it weak, segmenting strengthens it;
5) Fit flexible joints at the inlet and outlet to isolate vibration: because isolation cuts transmission, flexibility isolates it;
6) Torque the flange bolts to the anti-loosening value: because vibration loosens and leaks, they are locked tight;
7) Measure the lateral amplitude at trial run ≤0.1mm: because the design requires measurement, delivery is confirmed;
8) Include the guiding and the frequency calculation in the piping design: the original lack of guiding was the root cause of the resonance, so the design must cover it.
GB/T 50275-2010 Fan, Compressor and Pump Installation Code