Knowledge Base › Fluid Systems Error Case › Cryogenic Valve Without a Long Bonnet Freeze-Cracks the Packing

Cryogenic Valve Without a Long Bonnet Freeze-Cracks the Packing

E44-263 · Valve Selection and Internal Leakage · Cryogenic gate valve DZ61Y-40P DN50 · ★★★

Problem Description

At -196℃ the stem packing freeze-cracks and leaks liquid nitrogen about 2L/min; 30cm of frost forms on the bonnet

Root Cause

[Mechanism] A short bonnet conducts cold up to the stuffing box; <-40℃ it freezes and expands, cracking the packing.
[Calculation] The stem shrinks 2mm in the cold, losing packing compression and leaking.
[Design Omission] No long bonnet and no cryogenic packing for low temperature - the valve freeze-cracked.

Corrective Solution

1) Switch to a long bonnet (neck ≥150mm) to isolate cold, since the short bonnet took packing <-40℃ and freeze-cracked it leaking 2L/min, stopping cold conduction;
2) Use -196℃-rated flexible graphite packing plus disc springs, since ordinary packing fails cold and the 2mm stem shrink loosened it, sealing even at low temperature;
3) Add cold insulation to the bonnet to cut frosting, since the 30cm frost shows large heat leak, insulating the cold;
4) Add thermal compensation to the stem against shrink-loosening, since the 2mm shrink lost compression, compensating to hold pressure;
5) Run a -196℃ cold seat test, since room-temperature acceptance doesn't cover low temperature, checking it cold;
6) Use austenitic stainless steel for the body against cold brittleness, since low-temp carbon steel brittle-fracts, resisting cold;
7) Add leak collection and alarm, since liquid-nitrogen leak carries an asphyxiation risk, keeping it controlled;
8) Write the long bonnet and cryogenic packing into the design, since their absence was the root cause, closing the loop at design.

Checklist

Reference

GB/T 24925-2010 Cryogenic valves - Technical specifications