E44-257 · Valve Selection and Internal Leakage · Pilot-operated pressure reducing valve Y43H-16 DN65 · ★★
Outlet pressure swings 0.45-0.62MPa (set 0.5MPa); downstream over-pressure protection trips falsely twice a week
[Mechanism] Main-valve diaphragm fatigue lowers stiffness, and the set point drifts ±0.1MPa.
[Calculation] A clogged pilot orifice makes control pressure unstable and the main-valve opening erratic.
[Design Omission] No stabilizing tank and no fast-responding valve were chosen - regulation was unstable.
1) Fit a stable-stiffness diaphragm and set 0.5MPa, since the fatigued diaphragm drifted ±0.1MPa, returning the set point to stability;
2) Clean the pilot orifice and add a strainer, since a blocked orifice made control pressure and opening erratic, cleaning the pilot pressure;
3) Add an outlet stabilizing tank (volume ≥5× pipe volume), since the fluctuation is transient, smoothing it out;
4) Choose a fast-acting direct-operated regulator, since pilot-operated units lag noticeably, tracking quickly;
5) Add a downstream relief valve as over-pressure backup, since the drift caused false trips twice a week, covering the worst case;
6) Periodically calibrate outlet pressure and log drift, since diaphragm aging is gradual, catching it early;
7) Fit an isolating globe valve upstream of the regulator for maintenance, since it's hard to replace under pressure, enabling isolation;
8) Put stabilizing measures into the piping design, since the missing tank was the root cause of drift, closing the loop at design.
GB/T 12244-2006 Pressure reducing valves - General requirements