E44-328 · Excessive Piping Resistance and Pressure Drop · Carbon-Steel Pipe DN200 with 6m Support Spacing · ★★
Support spacing of 6m exceeded the design 4m, sagging the pipe 25mm, adding a bend effect, and raising local loss 0.03MPa.
[Sag] A long span lets the pipe sag under its own weight, tilting the section and distorting the flow path.
[Added Loss] The sag equals an extra bend, raising local loss 0.03.
[Design Omission] Support spacing was not set by stiffness and deflection was not checked; supports were too sparse.
1) Cut support spacing to ≤4m and check by stiffness; 6m sagged 25mm and raised local loss 0.03, so control sag to hold shape;
2) Add a cradle support on the sagging run to restore position; sag distorts flow, so reset it;
3) Check deflection ≤L/500; large sag shows clear loss, so limit deflection;
4) Add guide supports to prevent sway; sway causes vortex loss, so guide it;
5) Keep insulation / cold-weather layer even against offset weight; offset weight adds sag, so even the layer;
6) Periodically measure deflection to find loose supports; a loose support sags, so inspect supports;
7) Densify supports for large-diameter pipe; large diameter means heavy self-weight, so densify them;
8) Record support spacing in the layout; the original sparse spacing was the root cause of sag, so the layout must gate it.
GB/T 20801.3-2020 Design code for industrial metallic piping