E44-327 · Excessive Piping Resistance and Pressure Drop · Compressed-Air Pipe End Ma=0.7 · ★★
At Ma=0.7 near sonic speed, compressible friction ran 40% higher than incompressible, and end pressure dropped 0.15MPa.
[Compressible] High Ma makes density fall along the line and velocity rise; friction is 40% higher than incompressible.
[Pressure Drop] End pressure falls 0.15 because of compressible loss.
[Design Omission] Ma was not controlled ≤0.3 and a compressible method was not used; near-sonic resistance was high.
1) Enlarge the pipe to hold end Ma≤0.3; Ma=0.7 raised compressible loss 40% and dropped 0.15, so lower Ma to stabilize density;
2) Check pressure drop by compressible flow (Fanno); the incompressible formula under-predicts, so compute accurately;
3) Reduce pressure in stages to stabilize Ma; long lines raise Ma, so stage it;
4) Raise inlet pressure to lower Ma; high pressure means high density and low speed, so raise pressure;
5) Check end pressure with margin; the drop causes shortage, so leave margin;
6) Monitor flow velocity to prevent near-sonic speed; a hidden rise is hard to notice, so monitor v;
7) Use short straight runs to cut compressible accumulation; long runs raise Ma, so lay them short;
8) Record compressible characteristics in the design; the original failure to control was the root cause of resistance, so the design must gate it.
GB/T 20801.3-2020 Design code for industrial metallic piping