Cage Valve Throttling Vibration

E44-846 · Throttling Noise and Vibration · Cage valve · ★★

Problem Description

A DN200 cage valve at Δp2.2MPa had a cage natural frequency of 85Hz near the fluid pulsation frequency of 82Hz, giving a stem amplitude of 0.4mm

Root Cause

[Mechanism] The multi-stage pressure reduction of a cage valve produces periodic pressure pulsation, and when the frequency approaches the cage's structural natural frequency it triggers resonant amplified vibration.
[Calculation] Pulsation frequency f=St·v/d=0.2×30/0.073≈82Hz, cage natural frequency fn=85Hz, frequency difference 3Hz<5% enters resonance; the amplitude is amplified by Q=15.
[Design Omission] No calculation of the cage natural frequency, no reinforcement, no vibration test.

Corrective Solution

1) Verify the natural frequency (change the cage wall thickness so fn deviates from the pulsation frequency by ≥30%, i.e. >107Hz), since the original 85Hz≈82Hz resonance amplified vibration, thus verifying the frequency avoids vibration;
2) Add a locating pin (a double pin on the cage to prevent radial sway), since loose vibrates and fixing steadies it, thus reinforcing;
3) Add a damping ring (silicone-oil damping cuts the Q value from 15 to 4), since oscillation vibrates and damping suppresses it, thus adding damping;
4) Avoid the resonance region (adjust the operating condition so the pulsation frequency is away from fn), since entering it vibrates and avoiding keeps it safe, thus avoiding the region;
5) Monitor the vibration (an accelerometer on the stem, alarm >0.2mm), since gradual vibration approaches cracking and early detection catches it, thus monitoring vibration;
6) Run a vibration test (excite and measure the frequency-response curve), since the lack of testing left the vibration undetected and the test reveals the resonance peak, thus testing vibration;
7) Control the velocity to steady it (limit v≤25m/s), since changing conditions drift the frequency near the natural one and steadying moves it away, thus controlling speed;
8) Write the frequency verification and reinforcement into the specification, since the original lack of verification is the root cause of vibration and locking it in closes the loop, thus controlling it in the spec.

Checklist

Reference

GB/T 11349.1-2006 Mechanical vibration and shock

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL