E44-654 · Level Control Failure · Steam-heated tank · ★★
Heating expanded the liquid, level rose, high
[Mechanism] Heating expands the liquid and raises the level.
[Calculation] The expansion raises the level.
[Design Omission] No allowance was made for thermal expansion, no control and no relief — so the level rose.
1) Allow for thermal expansion (operate at a level ≤85%, leaving room to expand): because the original heating raised the liquid temperature (ΔT=40℃), expanding the volume by about 4% and driving the level to overflow, leaving expansion room prevents it so it does not overflow;
2) Control the heating rate (heat-up ≤10℃/min): because rapid heating surges the level and a slow rise evens it, the level is stable;
3) Provide an overflow return (overflow to a buffer tank): because a high level overflows and the return collects it, it does not overflow;
4) Verify the thermal expansion coefficient (computed with β = the volumetric expansion coefficient): because a change in conditions raises the level and verifying the expansion reveals the allowance, enough room is left;
5) Monitor the upper level (a high alarm plus a high-high interlock stopping the heating): because a high level overflows and monitoring gives warning, overflow is prevented;
6) Limit the feed (reduce it during heating): because feeding raises the level and limiting steadies it, the level is controlled;
7) Run a heat balance calculation (compute the level by mass conservation): because the uncalculated rise caused the overfill and calculating predicts it, overflow is prevented;
8) Write the expansion allowance and rate control into the specification: the original lack of an allowance was the root cause of the level rise, so the spec locks it in and specification governs it.
GB/T 151-2014 Heat exchangers