E44-713 · Hydraulic System Contamination and Crawling · Contamination Level · ★★★
Limit exceeded, jamming, NAS>11
[Mechanism] Excessive contamination jams the valve.
[Calculation] Exceeding the limit causes jamming.
[Design Omission] No control, no filtration, and no inspection - a design defect leading to excessive contamination.
1) Control contamination to NAS 8 (online monitoring, alarm at >9); the original NAS 12 level let >10μm particles jam the valve and disable operation, so controlling the class prevents jamming;
2) Upgrade filtration precision (β10≥200, 5μm); coarse filtration lets the limit be exceeded, so upgrading cleans the oil and lowers contamination;
3) Add a bypass circulation loop (flow ≥20% of system flow); accumulation causes the limit to be exceeded, so bypass cleaning removes it;
4) Schedule oil-sample inspection (every 500h, NAS level); the gradual exceedance is quantified, so oil is changed on data;
5) Change oil until the target is met (to NAS 8); exceeding limits causes jamming, so changing oil restores cleanliness;
6) Clean the valve and remove particles (disassemble and flush); jamming disables operation, so cleaning restores movement;
7) Seal off repair work against contamination (clean, isolated); repair work raises contamination, so sealing protects against it;
8) Write contamination control class and filtration upgrade into the maintenance card (NAS target); since lack of control was the root cause of the exceedance, closing the loop in the maintenance card gives maintenance control.
GB/T 3766-2015 General technical conditions for hydraulic systems