MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Check-Valve Slamming Water Hammer

Check-Valve Slamming Water Hammer

E44-1041 · Water Hammer and Pressure Surge · Check Valve · ★★

Problem Description

Slamming hammer, noise, and vibration.

Root Cause

[Mechanism] On reverse flow, a conventional swing check valve slams its disc shut rapidly, striking the valve body and triggering water hammer.
[Calculation] DN250 swing check, reverse-flow velocity 1.8m/s; the slamming disc momentum creates a local ΔP=1.5MPa, three times the static pressure, with 95dB noise.
[Design Omission] No slow-closing check selection, no reverse-velocity check, and no impact calculation.

Corrective Solution

1) Switch to a slow-closing check valve (damped disc seating); slamming caused the impact, and slow closure reduces it, so stop the slam;
2) Check the reverse-flow velocity ≤0.5m/s (enlarge the pipe); excessive backflow caused the slam, and a speed limit eases it, so suppress the impact;
3) Add a dashpot (absorbs disc momentum); the violent slam caused the noise, and a cylinder absorbs it, so cut the noise;
4) Switch to a dual-plate check (light disc, fast close, low resistance); a heavy disc slams, and a light one stays stable, so reduce the hammer;
5) Run an impact test (measured ΔP≤0.6MPa, noise≤85dB); the slam had never been calculated, and the measurement confirms control, so set the impact by data;
6) Fit vibration/noise instruments (monitor the peak); the slam first shows as noise, so monitor and give early warning;
7) In operation, control slow closure of the pump discharge valve (prevent backflow); backflow causes the slam, and controlling it protects, so prevent impact in operation;
8) Write slow closure and speed check into the specification; the root cause of the check-valve slam was no slow closure and high reverse velocity, so lock it in at specification level.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL