E44-930 · Siphon and Backflow · Vessel · ★★★

Problem Description

Backflow, overpressure, hazard

Root Cause

[Mechanism] The backflow medium keeps entering the closed vessel, raising the pressure above the allowable value and creating an overpressure hazard.
[Calculation] A backflow of 0.3 m³/h enters the closed vessel, raising the pressure 0.05 MPa/h and exceeding the 0.4 MPa design limit in 8 h.
[Design Omission] No check valve, no pressure check, and no safety relief.

Corrective Solution

1) Install a check valve plus fast shutoff at the inlet (shut off on backflow), because backflow is the overpressure source and cutting it off stops the pressure rise, thereby preventing overpressure;
2) Provide a safety valve on the vessel (set ≤0.4 MPa, discharge ≥ twice the backflow rate), because it relieves on overpressure and keeps the vessel from bursting, thereby providing safety relief;
3) Check that the backflow rate matches the relief capacity (relief ≥0.6 m³/h > backflow 0.3), because a relieved margin keeps the pressure from rising, thereby stabilizing the pressure;
4) Fit the vessel with a pressure alarm (alarm at ≥0.35 MPa), because overpressure first shows as a pressure rise before the hazard, thereby monitoring the pressure for early warning;
5) Perform an overpressure test (verify the safety valve lifts), because the design omitted the relief check and the test confirms the lift pressure, thereby sizing the valve from data;
6) Provide level interlocking to close the valve on the backflow side, because a high level causes backflow and the interlock cuts off at once, thereby controlling the source to prevent overpressure;
7) Control the operating vessel pressure ≤0.35 MPa with an alarm, because a stable pressure prevents overpressure and controlling it prevents hazard, thereby keeping operation safe;
8) Write the check valve and safety valve into the vessel regulations, because the root cause of overpressure is backflow without relief, so the regulations must govern to prevent hazard.

Checklist

Reference

GB/T 150.1-2011 Pressure vessels

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL