E44-406 · Two-Phase Flow and Air Binding · Condensate Return with 20% Gas Content · ★★
20% gas content makes two-phase friction 2.3× the single-phase value; hf=0.25MPa exceeds the 0.1 limit, and condensate return is sluggish.
[Two-Phase] The gas phase occupies 20% of the section, reducing the effective flow area and multiplying the friction.
[Rising Resistance] hf=0.25 over 0.1 makes the condensate return sluggish.
[Design Omission] No venting up front and no two-phase calculation — high two-phase resistance.
1) Fit vent valves at high points to vent first, since 20% gas gives 2.3× friction and hf=0.25 over 0.1 — thus clearing gas to cut resistance;
2) Check hf with a two-phase (Lockhart-Martinelli) model, since the single-phase formula undercounts — thus sizing it correctly;
3) Enlarge the bore to accommodate the gas, since gas occupies the section — thus upsizing;
4) Add gas-liquid separation at the pump suction, since gas entering the pump hurts it — thus separating;
5) Hold the gas fraction ≤5%, since more gas multiplies resistance — thus controlling gas;
6) Fit collecting pots at high points, since gas collects at the top and blocks flow — thus gathering it;
7) Lay the line on a slope to favor venting; flat piping traps air, so slope the layout;
8) Write the two-phase behavior into the design, since the unchecked gas was the root cause — thus locking it in at design.
GB/T 5657-2013 Technical specifications for centrifugal pumps