E44-407 · Two-Phase Flow and Gas Binding · Riser Upward Liquid Delivery · ★★
In an upward riser, gas accumulates together with the rising liquid; a local gas pocket causes ±30% flow pulsation and pump surging.
[Mechanism] On the upward run the gas collects at the top of the pipe, blocks the flow, and causes flow pulsation.
[Calculation] The pulsation makes the pump surge.
[Design Omission] No venting was provided on the riser and dissolved gas was not controlled — the cause of the upward gas binding.
1) Fit a vent valve at the riser top for continuous venting; gas collecting at the top blocks the flow and causes ±30% pulsation and surging, so top venting clears the blockage;
2) Keep the upward velocity high so the liquid carries the gas along; at low v the gas collects, so raise v;
3) Install gas-liquid separation to keep gas out; the gas source is at the pump, so separate it there;
4) Check the riser liquid holdup and gas resistance; gas binding causes loss, so verify the resistance;
5) Fit anti-surging protection on the pump; surging causes damage, so protect against it;
6) Periodically vent the riser; buildup is gradual, so vent and inspect;
7) Avoid long straight upward runs in the layout; long runs bind easily, so keep them short;
8) Write riser venting into the design; the original lack of venting was the root cause of the binding, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps