MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › External Pressure Instability Collapses the Vessel

External Pressure Instability Collapses the Vessel

E44-960 · Insufficient Vessel Strength and Wall Thickness · Vessel · ★★★

Problem Description

external pressure,collapse,deformation

Root Cause

[Mechanism] The stability of the vessel under external pressure (vacuum or jacket cooling) was not checked; the critical external pressure is below the operating external pressure and the shell buckles and collapses.
[Calculation] With an operating external pressure of 0.08 MPa, DN1800, L=6 m and δ=8 mm, the critical external pressure is only 0.05 MPa, 38% below operating, so it buckles.
[Design Omission] External-pressure stability was not calculated, no stiffening rings were added and no vacuum breaker was provided.

Corrective Solution

1) Calculate the stiffening-ring spacing Ls for external-pressure stability (originally none; add 3 rings at 1.5 m spacing); no rings lower the critical pressure while rings raise stability, thus preventing collapse;
2) Verify the critical external pressure Pcr>0.08×1.1=0.088 MPa (originally 0.05 MPa); higher pressure causes instability while verifying stability ensures safety, thus making stability compliant;
3) Increase the wall thickness to 10 mm (originally 8 mm); a thin wall lowers the critical pressure while thickening raises stability, thus reinforcing;
4) Install a vacuum breaker (opens when the pump stops); negative pressure collapses the vessel while breaking the vacuum restores it, thus isolating the vacuum;
5) Perform an external-pressure test (draw a vacuum to 0.1 MPa and hold); because stability was not calculated, verify no collapse by measurement, thus determining stability from data;
6) Install a vacuum gauge + alarm (alarm at <-0.088 MPa); instability first shows as vacuum before collapse, thus monitoring vacuum for early warning;
7) Keep the operating external pressure ≤0.08 MPa (adjust if exceeded); exceeding the critical value collapses the vessel while controlling pressure prevents collapse, thus preventing collapse in operation;
8) Write the stability calculation and added rings into the calculation sheet; since the root cause of collapse is the omitted external-pressure stability calculation and the lack of rings, the calculation serves as a gate to prevent collapse.

Checklist

Reference

GB/T 150.1-2011 Pressure vessels

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL