E44-284 · Valve Selection and Internal Leakage · Fully welded ball valve Q361F-25 DN150 · ★★
After the seat leaked, it could not be repaired online and the whole valve was scrapped; line stoppage was 8h for valve replacement, losing production.
[Not Serviceable] The fully welded structure makes the seat non-replaceable, so a micro-leak scraps the whole valve.
[Seepage] Seat elastomer decay causes seepage.
[Design Omission] A fully welded valve was wrongly chosen for a service needing maintenance, with no replaceable seat — the ball valve was scrapped.
1) For services needing maintenance, choose a split ball valve with a replaceable seat; a fully welded valve is scrapped at any micro-leak and stopped the line 8h, so make it serviceable;
2) Use a long-life seat elastomer to extend the replacement interval; decay causes seepage, so extend life;
3) Add an online leak-detection hole for early seepage notice; seepage grows, so diagnose early;
4) Stock an identical spare valve at critical points for quick exchange; once scrapped it must be swapped, so keep spares;
5) Periodically run tightness tests; micro-leaks are hard to notice, so verify the seal;
6) Use fully welded valves only for buried service with high reliability requirements; buried valves cannot be repaired and must be maintenance-free, so fit by scenario;
7) Add a bypass so the valve can be isolated for repair; once scrapped isolation is hard, so make it isolatable;
8) Include serviceability in selection; the wrong choice was the cause of scrapping, so gate it at design.
GB/T 12237-2007 Steel ball valves for petroleum, petrochemical and related industries