Knowledge Base › Fluid Systems Error Case › Parallel Piping Flow Deviation

Parallel Piping Flow Deviation

E44-725 · Uneven Flow Distribution · Parallel piping · ★★

Problem Description

Flow deviation, 30% flow difference, unequal resistance

Root Cause

[Mechanism] A resistance difference deviates the flow.
[Calculation] The resistance difference creates a 30% flow difference.
[Design Omission] No resistance balancing, no adjustment, and no inspection were provided, so the resistances differ.

Corrective Solution

1) Balance the resistance of each branch (adjust valves + orifices so the Δp of each branch differs by ≤2%), because the original branch resistance difference made the flow deviate by up to 30% and the two branches deliver unequal flow, thereby balancing the resistance and evening the flow;
2) Provide a balancing valve (each branch with an indicator, adjust to a flow deviation ≤5%), because a deviation makes the flows vary and adjustment evens them, thereby balancing;
3) Standardize the branch pipe diameter (same diameter and length on each branch, deviation ≤3%), because a diameter difference makes the resistance differ and standardization evens it, thereby standardizing the diameters;
4) Verify the flow of each branch (calibrate each branch, record the deviation), because doubt means deviation and verification reveals it, thereby verifying the flows;
5) Add restrictor orifices (size each orifice to its design flow, β = 0.5), because fighting for flow causes deviation and restriction splits it, thereby restricting the flow;
6) Monitor the flow deviation (fit a flowmeter on each branch, alarm above a 5% deviation), because gradual deviation is invisible and monitoring catches it, thereby giving early warning;
7) Keep the total flow steady (stable pump frequency, fluctuation ≤2%), because changing conditions cause deviation and control steadies them, thereby steadying the total flow;
8) Write the resistance balancing and flow evening into the hydraulic calculation sheet (resistance check for each branch), because the missing balancing was the root cause of the resistance difference and freezing it into the calculation sheet enforces control.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »