E44-795 · Piping Supports and Thermal Expansion · Support · ★★

Problem Description

Support interfered, pipe rubbed, wall thinned

Root Cause

[Mechanism] Insufficient clearance between the support and the pipe causes interference and rubbing.
[Calculation] The interference makes them rub in contact, thinning the wall >0.3mm per year.
[Design Omission] Neither clearance was left nor the position checked — so clearance must be left.

Corrective Solution

1) Leave an interference clearance (leave ≥3mm of running clearance between the pipe and the support): because the original interference made them rub in contact and thinned the wall >0.3mm per year, the clearance prevents the rub;
2) Check the support position (centered on the pipe axis, deviation ≤2mm): because offset interferes and the check corrects it, the position is checked;
3) Add a pipe-protection pad (a non-metallic pad insulates the hard contact): because hardness rubs and a pad protects, the pad is added;
4) Weld stops against collision (stop blocks limit the displacement): because movement interferes and a stop prevents it, collision is prevented;
5) Monitor the interference (measure the clearance, alarm on contact): because progressive interference worsens the rub and early awareness helps, interference is monitored;
6) Control the thermal displacement (provide compensation to absorb expansion and cut the interference): because expansion interferes and control relieves it, the displacement is controlled;
7) Perform a position test (record the actual clearance in the hot state): because the original lack of testing left the interference undiscovered, the test reveals the true clearance, so the position is tested;
8) Write the clearance allowance and position check into the assembly card: the original lack of clearance was the root cause of the interference, so assembly controls the work and the pipe is not rubbed.