E44-1058 · Filter Blockage and Fouling · Filter · ★★
Installed backwards, blocked, pressure drop
[Mechanism] The filter is installed backwards, the mesh faces the outlet side, and impurities enter the cartridge interior, which is hard to clean and highly resistant.
[Calculation] DN150 installed backwards, cartridge loaded in reverse, ΔP 0.2MPa higher than in the correct direction, cleaning requires dismantling the whole unit, 50% blocked.
[Design Omission] Flow direction not checked, no arrow marked, direction not inspected.
1) Reinstall in the flow direction (arrow following the medium), because reverse installation raises resistance and correct installation lowers it, so resistance drops;
2) Mark a clear flow-direction arrow (visible paint mark), because blind installation causes reversal and marking makes it clear, so direction is controlled;
3) Reinstall correctly (confirm the cartridge pressure-loading direction), because reverse installation blocks it and correct installation opens it, so flow is clear;
4) Run a resistance test (forward ΔP≤0.1), because the reverse case was not checked and measurement confirms the drop, so direction is set by data;
5) Install a differential gauge (monitor forward/reverse ΔP difference), because reversal first shows as high differential pressure and early notice helps, so direction is monitored and warned;
6) Perform a direction recheck (tag each unit), because mixing causes reversal and checking confirms it, so wrong installation is prevented;
7) Control mounting position in operation (forbid reverse mounting), because mistakes cause reversal and controlled positioning corrects it, so operational reverse-mounting prevention is applied;
8) Write direction check and flow marking into the assembly card, because the root cause of reverse installation was an unchecked flow direction and no marking, so the assembly card governs.
HG/T 21637-1991 Chemical-industry piping filters