Knowledge Base › Fluid Systems Error Case › Steam Ejector Insufficient Heat Transfer

Steam Ejector Insufficient Heat Transfer

E44-549 · Heat Exchanger Fouling and Insufficient Heat Transfer · Steam Ejector - Shell-and-Tube · ★★

Problem Description

Steam carries water, insufficient heat transfer, low vacuum

Root Cause

[Mechanism] Water-carrying steam worsens heat transfer.
[Calculation] Water carryover causes K to drop by 30% and vacuum to fall by 0.005, resulting in insufficient performance.
[Design Omission] No dry steam supply and no steam trapping were provided, causing insufficient heat transfer.

Corrective Solution

1) Supply dry steam (dryness ≥0.98) and provide steam trapping; because water-carrying steam worsens heat transfer, drops K by 30%, and lowers vacuum by 0.005, dry steam raises dryness and trapping restores K;
2) Maintain inlet steam dryness (install a steam-water separator at the inlet); because wet steam entering lowers the heat transfer coefficient and vacuum, maintaining dryness suppresses degradation;
3) Add vacuum monitoring (alarm when vacuum falls 0.005 below design); because water carryover first shows up as low vacuum before heat transfer declines, monitoring vacuum gives early warning;
4) Provide proper steam trapping (float / thermostatic steam traps); because a trap that blocks steam causes water accumulation and matched trapping keeps steam dry, trapping removes water;
5) Ensure adequate steam velocity (inlet steam velocity ≥ design lower limit); because insufficient steam velocity worsens heat transfer and lowers vacuum, adequate velocity preserves heat transfer;
6) Schedule water-carrying checks (inspect trap / separator each shift); because gradual water carryover lowers K, water inspection guides trapping;
7) Slope piping toward the drain point (slope lines toward the steam trap); because stagnant lines accumulate water and sloping facilitates drainage, sloped lines drain condensate;
8) Write dry-steam supply and steam trapping into the steam-ejector procedure; because the original design omitted dry steam and trapping, the root cause of water carryover, the procedure enforces control.

Checklist

Reference

GB/T 151-2014 Heat exchangers