E44-350 · Excessive Piping Resistance and Pressure Drop · Y-strainer before a pressure regulator clogged · ★★
A clogged upstream strainer raises the differential pressure to 0.09MPa (over 0.03), cuts downstream flow 20%, and makes the regulator shudder
[Mechanism] The upstream strainer clogs, pushing the differential pressure to 0.09 (over 0.03) and cutting downstream flow 20%.
[Calculation] The unstable pressure makes the regulator shudder.
[Design Omission] No strainer cleaning and no differential-pressure alarm - the clogged strainer raised resistance.
1) Fit a differential-pressure alarm on the upstream strainer and clean it regularly, since clogging pushed the delta to 0.09 over 0.03, cut flow 20% and caused shudder, cleaning the strainer to steady pressure;
2) Install twin strainers in parallel that can be switched over, since a single clogged strainer stops the line, allowing switchover;
3) Include strainer resistance in the total upstream resistance, since omitting it starved the downstream, accounting for it fully;
4) Coarsen the mesh to suit the medium, since too fine a mesh clogs easily, matching the mesh size;
5) Add a buffer tank upstream of the regulator to steady flow, since shudder caused instability, buffering it;
6) Periodically measure the pressure differential, since clogging creeps, measuring the delta;
7) Switch to a coarser strainer when the medium is clean, since too fine a mesh serves no purpose, coarse straining;
8) Write strainer maintenance into the procedure, since the missing cleaning was the root cause, closing the loop in the procedure.
GB/T 20801.3-2020 Design code for industrial metallic piping