E44-200 · Other · Restriction Orifice · ★★
A wrong bore made the medium vaporize, the orifice plug, and the flow stop.
[Wrong Size] Too small a bore gives a large pressure drop and vaporizes.
[Plug] Vaporization cokes and plugs.
[Design Omission] The bore / vaporization was not checked; plugging resulted.
1) Check the orifice bore for flow and vaporization; a small bore gives a large drop, vaporizes, cokes, and plugs, so compute the bore to prevent vaporization;
2) Verify the downstream pressure is above the vaporization pressure; low downstream pressure causes vaporization, so control it;
3) Choose a temperature-resistant material against coke adhesion; coke plugs it, so select the material;
4) Provide a bypass for clearing blockage; a plug can be cleared, so add a bypass;
5) Keep straight pipe upstream and downstream for steady flow; short runs disturb the flow, so use long straight runs;
6) Periodically check flow to detect plugging; it plugs gradually, so check periodically;
7) Verify stable flow without plugging on commissioning; design requirements need measured confirmation, so confirm at delivery;
8) Bring bore computation into restriction design; the original wrong size was the root cause of vaporization, so the design must include it.
GB/T 20801-2020 Pressure piping code