E44-635 · Level Control Failure · Blowdown valve · ★★
Leaking, level dropping, low
[Mechanism] The blowdown valve leaks and the level drops.
[Calculation] The leak lowers it.
[Design Omission] The valve was not tightened, not replaced and not inspected — so it leaked.
1) Tighten the blowdown valve to stop the leak (torque per the nameplate, stem reseated): because the original disc did not close tightly and leaked (about 0.5L/min), slowly lowering the level, tightening stops the leak so the level steadies;
2) Replace the disc seal (PTFE gasket or hard seat): because internal leakage lowers it and replacing the seal stops it, tightness is restored;
3) Add closed-position feedback (a limit switch confirms full closure): because a loose valve leaks and feedback confirms closure, leakage is prevented;
4) Calibrate the level against the sight glass (compare with the scale): because a deviation requires calibration and calibration corrects it, it is confirmed;
5) Select a corrosion-resistant valve (316L): because corrosion leaks it and corrosion resistance holds, its life is extended;
6) Check for leakage (inspect for moisture downstream of the valve weekly): because gradual leakage lowers the level and checking gives early warning, tightening is timely;
7) Limit the opening against misoperation (opening limited to ≤30%): because opening it by mistake leaks and limiting prevents it, misoperation is prevented;
8) Write the valve tightening and seal replacement into the maintenance card: the original lack of tightening was the root cause of the leak, so the card locks it in and maintenance governs it.
GB/T 12224-2015 Steel valves