E44-066 · Water Hammer and Pressure Surge · Siphon Penstock · ★★
A siphon priming loss forms an air cavity; on refilling the water column reverses into a water hammer, cracking and leaking the elbow weld.
[Cavity Reverse Flow] The siphon priming loss leaves an air cavity at the pipe crown; when the incoming water refills it, the water column accelerates backward and impacts.
[Calculation] A longer cavity raises the reverse-flow velocity v, and the impact Δp=ρcΔv exceeds the weld strength.
[Design Omission] No venting or priming-loss protection was provided and the reverse flow was never checked — the weld cracked.
1) Install air valves to prevent cavity formation: when the siphon loses prime, gas accumulates at the crown into a cavity; venting it away prevents the cavity and thus removes the precondition for reverse flow;
2) Provide priming-loss protection (auto pump trip on low level): the flow interruption is the root of the cavity; tripping the pump stops it and prevents the interruption at the operating level;
3) Reinforce the elbow weld and inspect it by NDT: the reverse-flow hammer strikes the elbow weld; reinforcement resists the impact and prevents cracking and leakage;
4) Fill slowly to reduce reverse-flow velocity: fast filling accelerates the water column into the wall; slow start-up lowers v, reducing Δp=ρcΔv;
5) Install pressure monitoring points along the line: the reverse-flow peak pressure occurs at the elbow and must be monitored, verifying the reinforcement;
6) Monitor level and pressure during filling: the cavity forms during the fill stage, so early detection allows timely intervention;
7) Run a commissioning test to verify there is no cavity reverse flow: siphon start-up is the most dangerous phase and must be measured on site, confirming that the protection works;
8) Build priming-loss protection into the siphon design: the original lack of protection caused the cavity reverse flow, so it must be considered at the design stage.
GB/T 20801-2020 Pressure piping code