E44-270 · Valve Selection and Internal Leakage · Jacketed ball valve BJQ41F-16 DN50 · ★★
Steam inflow to the jacket was zero; the body reached only 40℃ (the medium needs ≥80℃), so the medium solidified and plugged the line.
[Blockage] Rust scale and water scale inside the jacket blocked the passage, so the steam would not circulate.
[Condensate] Undrained condensate left half the jacket cold and defeated the heat tracing.
[Design Omission] No steam trap or flushing provision and no velocity control — the jacketed valve blocked.
1) Fit a steam trap at the lowest jacket point to drain condensate; pooling left half the jacket cold at only 40℃ and froze the medium, so drain freely to keep heat;
2) Add a strainer at the jacket inlet against rust-scale blockage; scale blocked the passage and kept steam out, so protect the jacket;
3) Periodically steam-flush the jacket; scale builds up gradually and blocks it, so clean the passage;
4) Add a vent on the jacket to remove non-condensable gas; gas binding stops steam circulation, so vent it;
5) Add heat-tracing tape outside the insulation as backup; it covers when the jacket becomes unstable, holding a constant temperature;
6) Keep the jacket steam velocity ≥1m/s to prevent deposition; low velocity promotes scaling, so keep it flowing;
7) Periodically measure the body temperature to confirm ≥80℃; temperature directly shows a blockage, so monitor it;
8) Include steam trapping and flushing in maintenance; the missing provision was the cause of blockage, so gate it in O&M.
GB/T 12224-2015 Steel valves — General requirements