MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Fluid Systems Error Case › Tank Breathing Contamination

Tank Breathing Contamination

E44-680 · Hydraulic System Contamination and Stick-Slip · Oil Tank · ★★

Problem Description

Breathing draws in contamination, dust

Root Cause

[Mechanism] Tank breathing draws contamination in.
[Calculation] Suction draws contaminants into the system.
[Design Omission] No breather valve, no filtration, and no inspection were provided, causing breathing contamination.

Corrective Solution

1) Fit an air-filtering breather (10 μm filter, with desiccant); because the tank breathed in dust and particles >10 μm entered the oil, jamming valves, filtering the intake air prevents contamination;
2) Add desiccant against moisture (silica gel, changed monthly); because humidity condenses water into the oil and emulsifies it and desiccant prevents it, this excludes water;
3) Seal the tank against dust (sealed manhole covers, tightened flanges); because an exposed tank lets dust in and sealing blocks it, this excludes dust;
4) Check the breather for clogging (differential pressure; a clogged breather draws in contamination under vacuum); because clogging draws in dirt and checking clears it, this keeps the breather open;
5) Clean dust off the tank top (weekly, wipe clean); because settling dust drops into the oil and cleaning removes it, this eliminates the source;
6) Keep the oil level steady (fluctuation ≤10%, against frequent breathing); because variable duty causes contaminated breathing and a steady level reduces it, this stabilizes the oil level;
7) Inspect the breather on schedule (every quarter, check desiccant color); because contamination builds up invisibly and inspection times the change, this follows the data;
8) Write breather filtration into the maintenance card (desiccant changed monthly); because the original lack of filtration is the root cause of breathing contamination and fixing it closes the loop, maintenance enforces control.

Checklist

Reference

GB/T 3766-2015 General technical conditions for hydraulic systems