E44-187 · Piping Supports and Thermal Expansion · Pump outlet cantilever pipe · ★★
A 1.5m unsupported cantilever at the pump outlet: vibration 4.5mm/s, flange loosened
[Cantilever] The long cantilever has a low modal frequency and vibrates easily.
[Vibration Loosening] The vibration loosens the flange.
[Design Omission] No intermediate support was set and no modal analysis made — causing the vibration.
1) Add an intermediate support to the pump outlet cantilever: because the 1.5m cantilever vibrated at 4.5mm/s and loosened, adding support damps the vibration;
2) Calculate the piping modal frequencies to avoid the excitation: because a low modal frequency vibrates easily, the frequencies are calculated to avoid resonance;
3) Add a damping layer to the support to dissipate energy: because vibration loosens the flange, damping is applied;
4) Reduce the cantilever length: because long is weak, the cantilever is shortened;
5) Torque the flange bolts to the anti-loosening value: because vibration loosens them, they are locked;
6) Fit a flexible joint at the outlet to isolate vibration: because vibration transmits, flexibility is used;
7) Measure the vibration at trial run ≤2.8mm/s: because the design requires measurement, delivery is confirmed;
8) Include the support and modal analysis in the piping design: the original lack of support was the root cause of the vibration, so the design must cover it.
GB/T 50275-2010 Fan, Compressor and Pump Installation Code