E44-1086 · Other · Safety Valve · ★★
Sluggish, leaking, poor pressure holding.
[Mechanism] An aged spring or stuck plug drifted the opening/reclosing pressure, lagging pressure holding.
[Calculation] Spring aged; opening pressure drifted from 1.0 to 1.3MPa; reseat at 0.7 (should be 0.9); pressure-holding lag 5s.
[Design Omission] No opening/closing pressure check, no plug cleaning, and no inspection.
1) Check opening/closing pressure (open 1.0 / reseat 0.9MPa); sluggishness causes poor holding, and a checked pressure restores holding;
2) Clean the plug (remove binding); binding causes sluggishness, and cleaning restores smooth opening;
3) Replace the spring (new part replacing aged); an aged spring causes sluggishness, and replacement restores timing;
4) Control temperature steadily (≤200℃ against aging); high temperature causes sluggishness, and temperature control protects, suppressing it;
5) Run an opening/closing test (opening/reseat pressure meets target); sluggishness was untested, and measured timing confirms it;
6) Install pressure monitoring (alarm on sluggishness); sluggishness first shows as overpressure, and early warning catches it;
7) Set a fixed calibration interval in operation (yearly); long intervals cause sluggishness, and controlled intervals calibrate, preventing it;
8) Record pressure check and plug cleaning on the safety-valve card; the root cause of sluggish operation was no check and an aged spring, so the card must gate it.
GB/T 12241-2005 Safety valves