Biased Flow in a Header

E44-777 · Uneven Flow Distribution · Header Pipe · ★★

Problem Description

Header biased, branch pipe robbing flow, deviation >15%

Root Cause

[Mechanism] A large header angle or misalignment causes biased flow.
[Calculation] A header angle >30° makes branch pipes rob flow and biases it >15%.
[Design Omission] The angle was not streamlined and no guide vanes were provided, so it had to be streamlined.

Corrective Solution

1) Streamline the header angle to prevent biased flow (branch pipes at an angle ≤30° to the header, joining on center), because the original large angle made the branches rob flow and biased it >15%, thereby distributing the flow evenly by streamlining the angle;
2) Calibrate the header resistance (measure the header pressure loss of each branch), because a difference biases the flow and calibration reveals it, thereby verifying the resistance by measurement;
3) Provide guide vanes (add guide vanes at the header inlet to reduce swirl), because disordered flow biases the distribution and guide vanes steady it, thereby distributing the flow evenly by guiding it;
4) Equalize the resistance of the branches (adjust valves so their header resistance matches), because a difference biases the flow and equalizing balances it, thereby distributing the flow evenly by equalizing resistance;
5) Monitor the deviation (monitor each branch's header flow, alarm above 10% deviation), because the deviation grows gradually and starves some branches and monitoring gives early warning, thereby monitoring the deviation;
6) Run a flow test (trace the flow field at the header inlet), because the omitted test let the bias go unnoticed, thereby proving even distribution;
7) Control the total pressure (keep the total flow steady against amplified bias), because off-design conditions worsen the bias and stabilization soothes it, thereby stabilizing the pressure;
8) Write the angle streamlining and guide vanes into the specification, because the omitted streamlining was the root cause of the header problem and the specification enforces it, keeping the header flow even.

Checklist

Reference

GB/T 20801.3-2020 Design code for industrial metallic piping

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL