E44-096 · Other · Steam Ejector Pump · ★★
Nozzle wear caused heavy cavitation noise; pumping capacity fell 25% and vacuum was insufficient.
[Wear] Nozzle wear changes the throat dimensions and lowers the entrainment ratio.
[Calculation] A 5% increase in throat wear lowers the entrainment coefficient and cuts suction by 25%.
[Design Omission] No periodic nozzle replacement and no pressure regulation; wear weakened suction.
1) Replace nozzles periodically (per the wear curve); a 5% throat wear lowers the entrainment coefficient and replacement restores it, so recover suction;
2) Regulate the working-steam pressure; pressure swings cause uneven wear, and regulation stabilizes the duty, extending life;
3) Harden the nozzle material (e.g., tungsten carbide); hard material resists cavitation erosion and wears slowly, extending the interval;
4) Check the entrainment ratio (pumped steam / working steam); a 25% suction loss needs quantification, and the check verifies it, confirming the target;
5) Check condenser capacity (to prevent high back-pressure drag); high back-pressure hampers pumping, and the check ensures a match, preserving vacuum;
6) Monitor pressure (steam pressure and vacuum); parameter drift causes the drop, and monitoring catches it early, so replace in time;
7) Measure vacuum on commissioning against design; insufficient vacuum is the result and must be measured, so accept by test;
8) Make nozzle replacement a mandatory maintenance item; the original lack of periodic replacement caused the wear loss, so control the interval during maintenance.
GB/T 150.3-2011 Pressure vessels - Design