E44-418 · Two-Phase Flow and Gas Binding · Storage Tank Breather Valve Blocked · ★★
A blocked breather valve lets the tank pressure swing ±8kPa during filling and emptying, collapsing or bulging the tank and lifting the safety valve.
[Mechanism] A blocked breather valve traps the pressure as the tank fills and empties.
[Calculation] The ±8kPa swing collapses or bulges the tank and lifts the safety valve.
[Design Omission] The breather valve was not kept clean and the breathing volume was not calculated — the cause of the breathing restriction.
1) Clean the breather valve and size its breathing capacity to match the pump rate; blocking causes ±8kPa swing, collapse/bulge and safety lift, so clean and match it;
2) Install twin breather valves for standby; a single valve blocking is a hazard, so provide dual protection;
3) Check the fill/draw breathing demand and select the valve bore; exceeding it pressurizes the tank, so verify the demand;
4) Size the tank shell stiffness for the ±pressure; collapse and bulge cause damage, so check the rigidity;
5) Periodically test the breathing action; blocking progresses gradually, so test it;
6) Add pressure alarms to catch pressurization early; trapped pressure is a hazard, so alarm it;
7) Use a nitrogen blanketing system to hold the pressure; an open vent pressurizes easily, so blanket with N2;
8) Write the breathing volume into the design; the original lack of calculation was the root cause of the restriction, so gate it at design stage.
GB/T 5657-2013 Technical specifications for centrifugal pumps