E44-705 · Hydraulic System Contamination and Crawling · Synchronous Cylinder · ★★
Loss of synchronization, offset
[Mechanism] Loss of synchronization causes positional offset.
[Calculation] Internal leakage causes the offset.
[Design Omission] No flow compensation, no control, and no inspection - a design defect leading to leakage.
1) Add a synchronization valve to equalize flow (flow-splitting accuracy ±1%); the original setup let the two cylinders offset >15mm and fall out of sync, so flow equalization restores synchronization;
2) Calibrate the cylinder strokes to match (stroke difference ≤1mm); stroke mismatch causes offset, so calibration aligns them for synchronization;
3) Check internal leakage and renew seals (hold-pressure test, replace seals); internal leakage causes offset, so checking and sealing restores synchronization;
4) Provide displacement feedback (compare the two cylinder positions, adjust any offset); running blind causes offset, so feedback closes the loop and corrects it;
5) Balance the loads (uniform distribution, difference ≤5%); load mismatch causes offset, so balancing keeps synchronization stable;
6) Check the offset (displacement; alarm at offset >5mm); gradual offset is invisible, so checking catches it early for early warning;
7) Schedule monthly synchronization inspection (record the offset); gradual offset is invisible, so scheduled inspection makes it measurable;
8) Write flow equalization and stroke calibration into the control card (synchronization test); since lack of equalization was the root cause of offset, fixing it in the control card gives control-system oversight.
GB/T 3766-2015 General technical conditions for hydraulic systems