E44-605 · Seal Leakage · Expansion Joint · ★★★
Joint ruptures and leaks, pressure exceeded
[Mechanism] A rating too low causes the joint to rupture.
[Calculation] Exceeding the pressure rating causes the rupture.
[Design Omission] The rating was never verified, the joint was not selected properly and it was not tested - the wrong joint was fitted.
1) Verify the pressure class and change to a suitable joint (PN25 matched to the actual pressure); the original class was low and the system pressure exceeded the rating so the joint ruptured and leaked, and verifying the class prevents the rupture;
2) Carry out a hydrostatic test (1.5 times the design pressure); without the test the rupture went undetected, so the test proves the strength;
3) Select a fatigue-rated joint (fatigue margin of at least 2x); fatigue causes rupture, and a fatigue-rated joint prevents that;
4) Add travel stops to prevent over-travel (limit rods); exceeding the travel ruptures the joint, and the stops prevent that;
5) Inspect the joint wall thickness (thickness measurement, replace if the reduction exceeds 10%); it thins gradually and then ruptures, so the thickness is inspected;
6) Control the temperature and pressure within the design values (reduce temperature and pressure); exceeding them ruptures the joint, and controlling the duty prevents that;
7) Avoid water hammer (venting and slow-opening valve); a surge ruptures the joint, and avoiding it prevents that;
8) Write the rating verification and the pressure test into the specification; the original failure to verify the rating was the root cause of the rupture, so the specification closes the loop.
GB/T 12777-2019 Metal Bellows Expansion Joints