E44-616 · Level Control Failure · Magnetic Flap · ★★
Flap stuck, no flipping
[Mechanism] The flaps stick and do not flip.
[Calculation] The sticking stops the flipping and freezes the indication.
[Design Omission] The magnet track was not cleaned, nothing was lubricated, and it was not inspected, so the flaps stuck.
1) Clean the flap magnet track to remove the sticking (clear debris from the guide rail, free clearance ≥2mm), because dust or rust on the guide rail jammed the flap pivots, so the float moved past while the flaps did not flip and the indication froze, and cleaning restores rotation, so the flaps flip with the float and the indication follows;
2) Lubricate the flap pivots (food-grade grease, 0.1mm pivot clearance), because dry friction rusts and seizes the pivots and lubrication cuts friction, thereby keeping the pivots free;
3) Replace the demagnetized float (magnetic flux density ≥0.05T, renew to avoid a weak magnet), because a demagnetized float magnet gives a force below the flap flipping resistance, so the flaps do not flip, while a strong magnet is sufficient, thereby driving the flaps;
4) Check the float magnet strength (measure the flux density, replace below 0.04T), because a weakening magnet stops the flipping and checking gives warning, thereby allowing timely replacement;
5) Widen the flap gap against sticking (increase the flap spacing from 2mm to 4mm), because too small a gap makes adjacent flaps stick together and widening separates them, thereby preventing sticking;
6) Check the flap condition (manually check flipping monthly), because gradual sticking freezes the indication and inspection catches it early, thereby preventing loss of indication;
7) Control media cleanliness (suspended solids <0.1%), because dirt builds up and jams the rail and cleanliness lowers the load, thereby extending the cleaning interval;
8) Write the magnet track cleaning and pivot lubrication into the maintenance card (interval ≤3 months), because the omitted cleaning and lubrication were the root cause of the sticking and freezing them into the maintenance card enforces maintenance.
HG/T 21550-1993 Magnetic flap level gauges